Engineered for safe and efficient fuel storage, the Durable Cube Self-Bunded Fuel Tanks integrate a double-walled design with a 110% spill containment capacity, ensuring compliance with international safety standards. Ideal for industrial, commercial, and remote site applications, these tanks balance rugged durability with space-efficient cubic geometry.
Dual-Layer Protection: Inner tank constructed from 5mm high-tensile steel; outer bund layer provides secondary spill containment, tested to withstand 10-year UV exposure without degradation.
Modular Interconnect System: Stackable design with quick-connect flanges allows seamless expansion of storage capacity by up to 50,000L per installation.
Integrated Safety Features: Automatic overfill prevention valves, temperature-sensitive pressure relief vents, and grounding terminals reduce operational risks.
Corrosion Resistance: Epoxy-polyester powder coating offers 3x better resistance to chemical spills and coastal humidity compared to standard tanks.
Construction Sites: Fuel storage for heavy machinery in remote locations, with forklift pockets enabling easy relocation.
Commercial Fleets: Centralized diesel storage for truck depots, featuring optional fuel management systems for real-time level monitoring.
Renewable Energy Farms: Backup fuel storage for generators in wind/solar installations, compliant with ISO 20885 environmental standards.
Compliance Assurance: Certified to EN 13160 and UL 142, with factory-applied fire-resistant insulation for high-risk environments.
Custom Configuration: Optional add-ons include spill pallets, heating jackets, and digital gauging systems tailored to project requirements.
Code | Gross Volume (L) | Safe Fill Level (L) | External Dimensions (L x W x H) (mm) | Tare Weight (kg) |
PC 0.66 | 660 | 600 | 1374 x 1086 x 810 | 451 |
PC 1.1 | 1100 | 1000 | 1374 x 1086 x 1270 | 594 |
PC 2.25 | 2250 | 2000 | 2294 x 1086 x 1270 | 885 |
PC 4.5 | 4500 | 4000 | 2294 x 2084 x 1270 | 1328 |
PC 6.6 | 6600 | 6000 | 2966 x 2294 x 1270 | 1809 |
PC 8.8 | 8800 | 8000 | 3916 x 2294 x 1270 | 2170 |
PC 11 | 11000 | 10000 | 4876 x 2294 x 1270 | 2689 |
Code | Gross Volume (L) | Safe Fill Level (L) | External Dimensions (L x W x H) (mm) | Tare Weight (kg) |
FC0.66 | 660 | 600 | 1374 x 1086 x 810 | 451 |
FC1.1 | 1100 | 1000 | 1374 x 1086 x 1270 | 594 |
FC2.25 | 2250 | 2000 | 2294 x 1086 x 1270 | 885 |
FC4.5 | 4500 | 4000 | 2294 x 2084 x 1270 | 1328 |
FC6.6 | 6600 | 6000 | 2966 x 2294 x 1270 | 1809 |
FC8.8 | 8800 | 8000 | 3916 x 2294 x 1270 | 2170 |
FC11 | 11000 | 10000 | 4876 x 2294 x 1270 | 2689 |
Engineered for safe and efficient fuel storage, the Durable Cube Self-Bunded Fuel Tanks integrate a double-walled design with a 110% spill containment capacity, ensuring compliance with international safety standards. Ideal for industrial, commercial, and remote site applications, these tanks balance rugged durability with space-efficient cubic geometry.
Dual-Layer Protection: Inner tank constructed from 5mm high-tensile steel; outer bund layer provides secondary spill containment, tested to withstand 10-year UV exposure without degradation.
Modular Interconnect System: Stackable design with quick-connect flanges allows seamless expansion of storage capacity by up to 50,000L per installation.
Integrated Safety Features: Automatic overfill prevention valves, temperature-sensitive pressure relief vents, and grounding terminals reduce operational risks.
Corrosion Resistance: Epoxy-polyester powder coating offers 3x better resistance to chemical spills and coastal humidity compared to standard tanks.
Construction Sites: Fuel storage for heavy machinery in remote locations, with forklift pockets enabling easy relocation.
Commercial Fleets: Centralized diesel storage for truck depots, featuring optional fuel management systems for real-time level monitoring.
Renewable Energy Farms: Backup fuel storage for generators in wind/solar installations, compliant with ISO 20885 environmental standards.
Compliance Assurance: Certified to EN 13160 and UL 142, with factory-applied fire-resistant insulation for high-risk environments.
Custom Configuration: Optional add-ons include spill pallets, heating jackets, and digital gauging systems tailored to project requirements.
Code | Gross Volume (L) | Safe Fill Level (L) | External Dimensions (L x W x H) (mm) | Tare Weight (kg) |
PC 0.66 | 660 | 600 | 1374 x 1086 x 810 | 451 |
PC 1.1 | 1100 | 1000 | 1374 x 1086 x 1270 | 594 |
PC 2.25 | 2250 | 2000 | 2294 x 1086 x 1270 | 885 |
PC 4.5 | 4500 | 4000 | 2294 x 2084 x 1270 | 1328 |
PC 6.6 | 6600 | 6000 | 2966 x 2294 x 1270 | 1809 |
PC 8.8 | 8800 | 8000 | 3916 x 2294 x 1270 | 2170 |
PC 11 | 11000 | 10000 | 4876 x 2294 x 1270 | 2689 |
Code | Gross Volume (L) | Safe Fill Level (L) | External Dimensions (L x W x H) (mm) | Tare Weight (kg) |
FC0.66 | 660 | 600 | 1374 x 1086 x 810 | 451 |
FC1.1 | 1100 | 1000 | 1374 x 1086 x 1270 | 594 |
FC2.25 | 2250 | 2000 | 2294 x 1086 x 1270 | 885 |
FC4.5 | 4500 | 4000 | 2294 x 2084 x 1270 | 1328 |
FC6.6 | 6600 | 6000 | 2966 x 2294 x 1270 | 1809 |
FC8.8 | 8800 | 8000 | 3916 x 2294 x 1270 | 2170 |
FC11 | 11000 | 10000 | 4876 x 2294 x 1270 | 2689 |